In an emergency equipment inner container
of the type RS 34; on opening the material of the inner container was ripped at the point
where the trigger release is fixed.
In agreement with the company Comet Sportartikel GmbH & Co KG the DHV decided on
the following safety measures as a precaution:
- The inner container for all emergency equipment of the type
RS 30 and RS 34 must be rechecked
- Faulty inner containers must be exchanged.
This airworthiness instruction comes into force when it is published in
the News for Paragliders and Hang Gliders (NfGH). The precautionary safety measure must be
carried out before the equipment is flown again.
Checks and exchange will be carried out by the company
Paracontrol-Schweiger und Schiszler GbR, Flintkaserne 36, D-83646 Bad Tölz, Tel. 0049 (0)
8041/8881.
Gmund, 31.03.2000
Klaus Tänzler
Managing Director |